Capacitor Stored Energy
Enter capacitance, voltage and a discharge resistor to get joules, charge, peak current and safe discharge time.
Step-by-step
- Enter valid values to begin.
Ideal capacitor charged to V, discharged through an ideal resistor (no ESR, leakage or dielectric absorption). Hazard thresholds (under 1 J low, 1–20 J caution, over 20 J high) are a conservative rule of thumb only, not a standard; IEC 62368-1 defines energy source classes and its own limits. 50 V is used as a commonly applied safe-touch level for the discharge target — check your applicable standard.
Capacitor Stored Energy: How Much Can It Actually Hurt You?
Core Engineering Principles
Energy in a capacitor is E = ½CV², and the square on the voltage is what bites. Double the voltage and you store four times the energy, which is why a 470 µF capacitor on a 400 V inverter DC bus holds far more than a 4700 µF part on a 24 V rail. We see the same thing in photoflash units: a few hundred microfarads charged to a few hundred volts, and the stored joules dump into a tube in microseconds. A bus capacitor shorted by a screwdriver is limited only by loop resistance, so expect a crater in the blade and a flash.
Treat “off” as a claim you must verify. Power-factor-correction and DC-bus capacitors rely on a bleeder resistor, often a few hundred kΩ, so the decay time constant can run to minutes, and a failed or open bleeder leaves the full charge sitting there. Dielectric absorption makes it worse: a capacitor shorted briefly can recover part of its voltage once the short is removed, so a “dead” cap can come back and bite. Before service we discharge through a resistor, measure, then leave a shorting strap on.
Ipeak = V / R • τ = R × C • t = τ × ln(V / 50) • Ppeak = V² / R
NEC & Standard References
IEC 62368-1 (audio/video, information and communication technology equipment) classifies energy sources and sets the safeguards, including decay of stored charge after the mains is removed; use its classes, not this page’s thresholds. NFPA 70E requires establishing an electrically safe work condition and verifying absence of voltage, and treats stored energy as a hazard that must be released or restrained. IEEE Std 18 covers shunt power capacitors, including their internal discharge resistors and discharge time requirements. Check the adopted edition.1. E = ½ × 470 × 10⁻⁶ × 400² = 37.6 J (37,600 mWs, about 0.0104 Wh).
2. Q = 470 × 10⁻⁶ × 400 = 188 mC.
3. Peak current V / R = 400 / 100 = 4 A; peak power V² / R = 1600 W, so use a pulse-rated resistor.
4. τ = 100 × 470 µF = 47 ms.
5. Time to fall to 50 V = τ × ln(400 / 50) = 47 × ln 8 = 97.7 ms; 5τ = 235 ms.
6. The 37.6 J sits above the 20 J rule-of-thumb line, so the page flags it as high hazard. The 100 Ω resistor works in about a tenth of a second; the unit’s bleeder may take minutes.
- Never short with a screwdriver. It welds and sprays molten metal; use a resistor on insulated leads.
- A “discharged” cap can recharge. Dielectric absorption brings the voltage back after a short, so re-measure after a few minutes.
- Series banks drift. Without balancing resistors, leakage mismatch overloads one capacitor, so check each cell separately.
- Ripple current heats the part. ESR times ripple squared shortens electrolytic life.
- Derate voltage. Run capacitors well below rating; this page’s thresholds are a rule of thumb, not a code limit.
Energy Stored in Common Capacitors
The square of the voltage dominates. A 470 µF capacitor at 400 V holds more than fifty times the energy of a 10,000 µF part at 12 V.
| C | 12 V | 48 V | 160 V | 400 V |
|---|---|---|---|---|
| 100 µF | 7.2 mJ | 115 mJ | 1.28 J | 8 J |
| 470 µF | 33.8 mJ | 541 mJ | 6.02 J | 37.6 J |
| 1,000 µF | 72 mJ | 1.15 J | 12.8 J | 80 J |
| 2,200 µF | 158 mJ | 2.53 J | 28.2 J | 176 J |
| 4,700 µF | 338 mJ | 5.41 J | 60.2 J | 376 J |
| 10,000 µF | 720 mJ | 11.5 J | 128 J | 800 J |
How Long Does a Capacitor Stay Charged?
With a bleeder or discharge resistor the voltage falls exponentially. The table uses 400 V down to 50 V as the target, but follow the discharge time stated by the equipment standard or manufacturer.
| Discharge R | 470 µF | 1,000 µF | 4,700 µF |
|---|---|---|---|
| 1 kΩ | 977 ms | 2.08 s | 9.77 s |
| 10 kΩ | 9.77 s | 20.8 s | 97.7 s |
| 100 kΩ | 97.7 s | 3.47 min | 16.3 min |
| 1 MΩ | 16.3 min | 34.7 min | 163 min |
A 1 MΩ bleeder on a 4,700 µF bank takes more than two hours to get below 50 V. Never assume the bleeder works: measure the terminals first.
Energy in Plain Terms
Joules are easier to feel as work. 37.6 J, the inverter bus in the worked example, is enough to throw a 1 kg weight nearly four metres into the air.
| Energy | Lifts 1 kg by | Lifts 5 kg by |
|---|---|---|
| 1 J | 0.10 m | 0.02 m |
| 10 J | 1.02 m | 0.20 m |
| 37.6 J | 3.83 m | 0.77 m |
| 100 J | 10.19 m | 2.04 m |
| 500 J | 50.97 m | 10.19 m |
Worked Example: Photoflash Capacitor
A 100 µF capacitor at 300 V stores E = ½ × 100×10−6 × 300² = 4.5 J, and Q = 30 mC. Through a 100 Ω resistor the peak current is 3 A and the time constant is 10 ms. Discharging to 50 V takes 10 ms × ln(300/50) = 17.9 ms. The energy is small compared with a power bus, but it can still give a painful shock and burn.
Capacitor Energy Questions
What is the formula for energy stored in a capacitor?
E = ½ C V², with C in farads, V in volts and E in joules.
Why is high voltage so much more dangerous?
Energy grows with the square of voltage, and high voltage also drives current through the body. Doubling the voltage gives four times the energy.
How do I discharge a capacitor safely?
Use a suitable resistor rated for the energy, not a screwdriver. Then measure the voltage, and keep a shorting strap on large banks while you work.
How long does a capacitor hold charge?
It depends on the bleeder or leakage path. Time to fall to a safe level is t = R × C × ln(V / Vsafe). Some film and bus capacitors hold charge for hours.
Does connecting capacitors in parallel change the energy?
Yes. Parallel capacitors add their capacitance, so at the same voltage the energy adds too.
Is the energy value the same as the energy delivered to a load?
It is the maximum available. A real load receives less, because resistance and the voltage drop during discharge lose part of it.