Ideal capacitor in series with a resistor R, sinusoidal steady state, RMS voltage. ESR, leakage, lead inductance and self-resonance are not included; above the self-resonant frequency the part is inductive and these results do not apply. Real capacitor values drift with tolerance, temperature, age and DC bias. The corner frequency fc = 1/(2πRC) is for the RC pair formed with the series resistance (0 Ω gives no corner).
Capacitive Reactance: How a Capacitor Resists AC
Core Engineering Principles
A capacitor passes current only while its voltage is changing, so its opposition to AC depends on how fast the voltage swings. We call that opposition reactance, XC = 1/(2πfC), and it falls as either frequency or capacitance rises. At DC the frequency is zero and XC is infinite, which is why a series capacitor blocks bias while letting signal through. Coupling capacitors use that; bypass capacitors shunt noise to ground. Keep XC well below the circuit impedance at the lowest frequency of interest.
Reactance is not resistance. Current leads voltage by 90°, so an ideal capacitor dissipates nothing and the energy swaps back and forth as reactive power Q = I²XC. That matters in the field. A capacitor-dropper supply lets a small film capacitor drop mains voltage without a heat sink, and motor-run and power-factor-correction capacitors supply leading var to cancel lagging motor current. A real part adds ESR, an inductance that makes it self-resonant (SRF), and drift in value. Above the SRF it behaves like an inductor, so a 100 nF part can be a poor bypass at 100 MHz.
|Z| = √(R² + XC²) • φ = −atan(XC / R) • I = V / |Z|
Q = I² × XC • fc = 1 / (2π R C)
NEC & Standard References
IEC 60050-131 is the International Electrotechnical Vocabulary entry that defines reactance, impedance and related circuit terms. IEC 60252-1 covers AC motor capacitors, including motor-run types, and sets tolerance and endurance requirements. IEC 60384-14 covers fixed capacitors for electromagnetic interference suppression and mains connection, the X and Y classes, and is the document to read before putting a dropper capacitor across the line. IEEE Std 18 covers shunt power capacitors used for power-factor correction. This is a calculation, not a compliance test; confirm against the adopted edition and the datasheet.1. XC = 1 / (2π × 60 × 10×10−6) = 265.26 Ω.
2. |Z| = √(10² + 265.26²) = 265.45 Ω.
3. Phase = −atan(265.26 / 10) = −87.84°, so current leads.
4. I = 230 / 265.45 = 0.8665 A.
5. Q = 0.8665² × 265.26 = 199.1 var leading.
6. Corner frequency of the RC pair fc = 1 / (2π × 10 × 10×10−6) = 1591.5 Hz.
- Ripple current heats the part. I²×ESR heating at high ripple current shortens electrolytic life; check the ripple rating.
- Derate the voltage. Pick a rating well above peak, not RMS, and allow for mains surges; for a 230 V line that means a peak near 325 V plus margin.
- Dropper supplies are not isolated. The whole circuit sits at mains potential, so use a rated X2 capacitor, a bleed resistor and an enclosure nobody can touch.
- Capacitance drifts. Tolerance, temperature, ageing and DC bias on ceramics all move C, and XC moves inversely, so dropper current moves with it.
- Watch the SRF. Above self-resonance the part turns inductive and the formula no longer applies.
Reactance of Common Capacitors
Reactance falls as frequency or capacitance rises, the opposite of an inductor.
| C | 50 Hz | 60 Hz | 1 kHz | 100 kHz | 1 MHz |
|---|---|---|---|---|---|
| 100 pF | 31.83 MΩ | 26.53 MΩ | 1.592 MΩ | 15.92 kΩ | 1.592 kΩ |
| 1 nF | 3.183 MΩ | 2.653 MΩ | 159.2 kΩ | 1.592 kΩ | 159.2 Ω |
| 100 nF | 31.83 kΩ | 26.53 kΩ | 1.592 kΩ | 15.92 Ω | 1.592 Ω |
| 1 µF | 3.183 kΩ | 2.653 kΩ | 159.2 Ω | 1.592 Ω | 0.1592 Ω |
| 10 µF | 318.3 Ω | 265.3 Ω | 15.92 Ω | 0.1592 Ω | 0.01592 Ω |
| 100 µF | 31.83 Ω | 26.53 Ω | 1.592 Ω | 0.01592 Ω | 0.001592 Ω |
Capacitor Dropper Currents
Capacitive droppers are sometimes used in small mains supplies. The circuit is not isolated and is dangerous to touch.
| C | At 50 Hz | At 60 Hz |
|---|---|---|
| 220 nF | 15.9 mA | 19.1 mA |
| 470 nF | 34.0 mA | 40.8 mA |
| 1 µF | 72.3 mA | 86.7 mA |
| 1.5 µF | 108.4 mA | 130.1 mA |
| 2.2 µF | 159.0 mA | 190.8 mA |
Which Capacitor for a Target Reactance?
| Target XC | 50 Hz | 1 kHz | 100 kHz | 1 MHz |
|---|---|---|---|---|
| 1 Ω | 3183 µF | 159.2 µF | 1.592 µF | 159.2 nF |
| 10 Ω | 318.3 µF | 15.92 µF | 159.2 nF | 15.92 nF |
| 100 Ω | 31.83 µF | 1.592 µF | 15.92 nF | 1.592 nF |
| 1000 Ω | 3.183 µF | 159.2 nF | 1.592 nF | 159.2 pF |
Worked Example: Sizing a Dropper Capacitor
For about 100 mA at 230 V, 50 Hz, C = I / (2πfV) = 0.1 / (2π × 50 × 230) = 1.38 µF, so a 1.5 µF X2-rated capacitor is the standard choice. Reactance is 2122 Ω. Add a bleed resistor and an enclosure nobody can touch, because the whole circuit sits at mains potential.
Capacitive Reactance Questions
What is capacitive reactance?
XC = 1 / (2πfC), the opposition a capacitor offers to AC, in ohms.
Why does reactance fall with frequency?
At higher frequency the capacitor charges and discharges more often, so more current flows for the same voltage.
Is reactance the same as resistance?
No. It stores energy and gives a 90° phase shift, so it uses |Z| = √(R² + XC²).
Why is current leading?
Current in a capacitor leads voltage by 90° because current flows first to build up the voltage.
Can I use it to reduce mains voltage?
Only with a properly rated X2 capacitor and full safety measures. The circuit is not isolated, so avoid it unless you are experienced.
Why does a 100 nF capacitor not bypass at 100 MHz?
Real parts have inductance and self-resonate. Above the SRF the capacitor behaves like an inductor.