RC Time Constant Calculator
Enter R, C and source voltage to get the time constant, charge milestones, cut-off frequency and capacitor energy.
Step-by-step
- Enter valid values to begin.
Ideal capacitor (no leakage or ESR) and ideal resistor driven by a constant source with a perfect switch. Real electrolytic capacitors have wide tolerance (often −20/+80% or ±20%) and leakage that stretches discharge times, and ceramics lose capacitance with DC bias. The 1.5× voltage-rating margin is a derating practice, not a standard. Rise time 2.2τ applies to a full step response from 0 to the final value.
RC Time Constant: The Curve Behind Every Timer and Filter
Core Engineering Principles
A capacitor charges through a resistor at a rate proportional to the voltage still missing. That one fact gives the exponential curve, and the only number that matters is τ = R × C. After one time constant the capacitor has covered 63.2% of the journey, after two 86.5%, after three 95.0%, after four 98.2% and after five 99.3%. We call five time constants “fully charged” in practice, but remember the curve never actually arrives. The same curve describes discharge, with the voltage falling to 36.8% after one τ.
The same τ sets the frequency behaviour. Take the output across the capacitor and you have a low-pass filter with a −3 dB point at fc = 1 / (2πRC); take it across the resistor and you have a high-pass with the same corner. The step response and the frequency response are two views of one product. Real capacitors depart from the ideal. An aluminium electrolytic can be 20% off in value and leaks, so a long delay built on one drifts with temperature and age. For a timing circuit we use film or C0G ceramics, and we keep the resistor well below the capacitor’s leakage resistance.
fc = 1 / (2πRC) • tr = 2.2τ • E = ½CV²
NEC & Standard References
IEC 60384-1 is the generic specification for fixed capacitors in electronic equipment; its sectional parts cover specific types such as aluminium electrolytics and ceramics. IEC 60063 provides the preferred values for R and C. IEEE Std 100 defines time constant and cut-off frequency. A voltage rating of at least 1.5× the working voltage is derating practice used here as a warning, not a standard requirement.1. τ = 10,000 × 100 × 10−6 = 1.000 s.
2. Voltage at 1τ to 5τ: 7.585 V, 10.376 V, 11.403 V, 11.780 V and 11.919 V.
3. Time to reach 6 V: t = −1 × ln(1 − 6/12) = 0.693 s.
4. fc = 1 / (2π × 1) = 0.159 Hz, and rise time = 2.2 s.
5. Stored energy = ½ × 100 µF × 12² = 7.2 mJ. The resistor burns the same 7.2 mJ while charging, whatever its value.
6. Rating check: 1.5 × 12 = 18 V, so 25 V passes.
- The cap is not at 5τ the moment you think. A logic input with a threshold near 70% of the rail sees “high” at about 1.2τ, so timers depend on the threshold, not just τ.
- Inrush through a small R is large. Peak current is Vs/R at the first instant; switch contacts and supply limits must survive it.
- Stored energy bites. A large capacitor on a high-voltage rail can hold a lethal charge long after power-off; bleed it and measure before touching.
- Leakage ruins long delays. Beyond a few seconds, use a larger C with a smaller R rather than a huge R.
Time Constants for Common R and C
| R | 1 nF | 100 nF | 1 µF | 10 µF | 100 µF |
|---|---|---|---|---|---|
| 1 kΩ | 1 µs | 100 µs | 1 ms | 10 ms | 100 ms |
| 10 kΩ | 10 µs | 1 ms | 10 ms | 100 ms | 1 s |
| 100 kΩ | 100 µs | 10 ms | 100 ms | 1 s | 10 s |
| 1 MΩ | 1 ms | 100 ms | 1 s | 10 s | 100 s |
Charging and Discharging by Multiples of τ
After 5τ the capacitor is within 1% of its final value.
| Time | Charged | Remaining on discharge |
|---|---|---|
| 0.5τ | 39.3% | 60.7% |
| 1τ | 63.2% | 36.8% |
| 2τ | 86.5% | 13.5% |
| 3τ | 95.0% | 5.0% |
| 4τ | 98.2% | 1.8% |
| 5τ | 99.3% | 0.7% |
How Long to Reach a Threshold?
A logic input with a threshold near 70% sees high at 1.2τ.
| Threshold | Time |
|---|---|
| 10% | 0.11τ |
| 50% | 0.69τ |
| 63.2% | 1.00τ |
| 70% | 1.20τ |
| 90% | 2.30τ |
| 95% | 3.00τ |
| 99% | 4.61τ |
Low-Pass Filter Cut-Off
The same R and C also set the corner frequency of a simple filter.
| R | 1 nF | 100 nF | 1 µF |
|---|---|---|---|
| 1 kΩ | 159.2 kHz | 1.592 kHz | 159.2 Hz |
| 10 kΩ | 15.92 kHz | 159.2 Hz | 15.92 Hz |
| 100 kΩ | 1.592 kHz | 15.92 Hz | 1.592 Hz |
Worked Example: Button Debounce
R = 10 kΩ and C = 100 nF give τ = 1 ms. A 70% logic threshold is reached at 1.20 ms, while discharge to 30% also takes 1.20 ms, so contact bounce shorter than about 1 ms is filtered out. The same pair is a low-pass filter with fc = 159 Hz.
RC Time Constant Questions
What is the RC time constant?
τ = R × C in seconds. It is the time to reach 63.2% of the final voltage while charging.
How long to fully charge?
Practically about 5τ (99.3%). A capacitor never reaches exactly 100%.
What is the discharge formula?
v(t) = V0 × e−t/τ. After one τ it is at 36.8%.
How is it related to cut-off frequency?
fc = 1 / (2πτ) for a first-order RC filter.
Does the supply voltage change the time?
No. The shape scales with the supply, so the time to reach a fraction stays the same.
What about electrolytic capacitor tolerance?
They can be 20% off and leak. Use film or C0G parts for accurate timing.