← Back to ElectroLab
Electronics & RFIEC 60384 • IEEE Std 100

RC Time Constant Calculator

Enter R, C and source voltage to get the time constant, charge milestones, cut-off frequency and capacitor energy.

τ = R × C  •  v(t) = Vs(1 − e−t/τ)  •  fc = 1 / (2πRC)
Calculated Result
—

Step-by-step

  1. Enter valid values to begin.

Ideal capacitor (no leakage or ESR) and ideal resistor driven by a constant source with a perfect switch. Real electrolytic capacitors have wide tolerance (often −20/+80% or ±20%) and leakage that stretches discharge times, and ceramics lose capacitance with DC bias. The 1.5× voltage-rating margin is a derating practice, not a standard. Rise time 2.2τ applies to a full step response from 0 to the final value.

IEC 60384 • IEC 60063 • IEEE Std 100 • Transient Response

RC Time Constant: The Curve Behind Every Timer and Filter

Core Engineering Principles

A capacitor charges through a resistor at a rate proportional to the voltage still missing. That one fact gives the exponential curve, and the only number that matters is τ = R × C. After one time constant the capacitor has covered 63.2% of the journey, after two 86.5%, after three 95.0%, after four 98.2% and after five 99.3%. We call five time constants “fully charged” in practice, but remember the curve never actually arrives. The same curve describes discharge, with the voltage falling to 36.8% after one τ.

The same τ sets the frequency behaviour. Take the output across the capacitor and you have a low-pass filter with a −3 dB point at fc = 1 / (2πRC); take it across the resistor and you have a high-pass with the same corner. The step response and the frequency response are two views of one product. Real capacitors depart from the ideal. An aluminium electrolytic can be 20% off in value and leaks, so a long delay built on one drifts with temperature and age. For a timing circuit we use film or C0G ceramics, and we keep the resistor well below the capacitor’s leakage resistance.

τ = R × C  •  v(t) = Vs (1 − e−t/τ)  •  t = −τ ln(1 − V/Vs)
fc = 1 / (2πRC)  •  tr = 2.2τ  •  E = ½CV²

NEC & Standard References

IEC 60384-1 is the generic specification for fixed capacitors in electronic equipment; its sectional parts cover specific types such as aluminium electrolytics and ceramics. IEC 60063 provides the preferred values for R and C. IEEE Std 100 defines time constant and cut-off frequency. A voltage rating of at least 1.5× the working voltage is derating practice used here as a warning, not a standard requirement.
Worked Example: Power-On Delay on a 12 V Line
Given: R = 10 kΩ, C = 100 µF, Vs = 12 V, starting at 0 V, capacitor rated 25 V.
1. τ = 10,000 × 100 × 10−6 = 1.000 s.
2. Voltage at 1τ to 5τ: 7.585 V, 10.376 V, 11.403 V, 11.780 V and 11.919 V.
3. Time to reach 6 V: t = −1 × ln(1 − 6/12) = 0.693 s.
4. fc = 1 / (2π × 1) = 0.159 Hz, and rise time = 2.2 s.
5. Stored energy = ½ × 100 µF × 12² = 7.2 mJ. The resistor burns the same 7.2 mJ while charging, whatever its value.
6. Rating check: 1.5 × 12 = 18 V, so 25 V passes.
Safety & Installation Rules
  • The cap is not at 5τ the moment you think. A logic input with a threshold near 70% of the rail sees “high” at about 1.2τ, so timers depend on the threshold, not just τ.
  • Inrush through a small R is large. Peak current is Vs/R at the first instant; switch contacts and supply limits must survive it.
  • Stored energy bites. A large capacitor on a high-voltage rail can hold a lethal charge long after power-off; bleed it and measure before touching.
  • Leakage ruins long delays. Beyond a few seconds, use a larger C with a smaller R rather than a huge R.

Time Constants for Common R and C

Time constant τ = R × C.
R1 nF100 nF1 µF10 µF100 µF
1 kΩ1 µs100 µs1 ms10 ms100 ms
10 kΩ10 µs1 ms10 ms100 ms1 s
100 kΩ100 µs10 ms100 ms1 s10 s
1 MΩ1 ms100 ms1 s10 s100 s

Charging and Discharging by Multiples of τ

After 5τ the capacitor is within 1% of its final value.

Fraction of the final value reached while charging and remaining while discharging.
TimeChargedRemaining on discharge
0.5τ39.3%60.7%
1τ63.2%36.8%
2τ86.5%13.5%
3τ95.0%5.0%
4τ98.2%1.8%
5τ99.3%0.7%

How Long to Reach a Threshold?

A logic input with a threshold near 70% sees high at 1.2τ.

Time to reach a threshold: t = −τ ln(1 − V/Vs).
ThresholdTime
10%0.11τ
50%0.69τ
63.2%1.00τ
70%1.20τ
90%2.30τ
95%3.00τ
99%4.61τ

Low-Pass Filter Cut-Off

The same R and C also set the corner frequency of a simple filter.

RC low-pass cut-off fc = 1 / (2πRC).
R1 nF100 nF1 µF
1 kΩ159.2 kHz1.592 kHz159.2 Hz
10 kΩ15.92 kHz159.2 Hz15.92 Hz
100 kΩ1.592 kHz15.92 Hz1.592 Hz

Worked Example: Button Debounce

R = 10 kΩ and C = 100 nF give τ = 1 ms. A 70% logic threshold is reached at 1.20 ms, while discharge to 30% also takes 1.20 ms, so contact bounce shorter than about 1 ms is filtered out. The same pair is a low-pass filter with fc = 159 Hz.

RC Time Constant Questions

What is the RC time constant?

τ = R × C in seconds. It is the time to reach 63.2% of the final voltage while charging.

How long to fully charge?

Practically about 5τ (99.3%). A capacitor never reaches exactly 100%.

What is the discharge formula?

v(t) = V0 × e−t/τ. After one τ it is at 36.8%.

How is it related to cut-off frequency?

fc = 1 / (2πτ) for a first-order RC filter.

Does the supply voltage change the time?

No. The shape scales with the supply, so the time to reach a fraction stays the same.

What about electrolytic capacitor tolerance?

They can be 20% off and leak. Use film or C0G parts for accurate timing.