Ferrite Core Inductor Turns
Find the turns for a target inductance from the core AL and check flux density against saturation.
Step-by-step
- Enter valid values to begin.
Defaults suit a typical FT50-43-class toroid (AL about 523 nH/N², Ae about 13.3 mm²); take AL, Ae and Bsat from the datasheet of your exact core and mix. AL tolerance of ±25% is common, and AL is a low-level, low-frequency figure that drops with frequency and DC bias. Bsat of 250 mT is a typical hot MnZn figure, and the warning threshold is 70% of it (a rule of thumb, not a standard). Copper resistivity is taken as 1.72×10−8 Ω·m at 20°C; winding capacitance, skin effect and window fill are not modelled. In Find N mode, B and wire figures use the nearest whole number of turns.
Ferrite Core Inductors: Turns from AL
Core Engineering Principles
Every ferrite core maker publishes an inductance factor, AL, in nH per turn squared. It bundles permeability and core geometry into one number. Inductance is AL times N², and that square is why the arithmetic bites: doubling the turns quadruples the inductance, and one turn too many or too few on a 14-turn coil moves you several percent. Take the AL from the datasheet of your exact core and mix, and remember the tolerance. ±25% is common for ungapped toroids, so measure the finished coil on an LCR meter.
The AL printed in the catalog is a low-frequency, low-level figure. Ferrite permeability falls with frequency, and each mix has its own useful range: a type 43 or 61 style mix is chosen for EMI chokes or RF work, a 77 style mix for power and low-frequency use. Pick by the datasheet curve, not by what is in the drawer. The other limit is DC bias. Flux density is B = L·I / (N·Ae), and once it approaches saturation the permeability collapses and your inductor stops being an inductor. MnZn ferrite saturates around 200–500 mT and loses margin when hot. An air gap lowers AL but lets the core carry much more current, which is how power-supply inductors are built.
B = L × I / (N × Ae) • Length = N × MTL • Rdc = ρ × length / (π d² / 4)
NEC & Standard References
IEC 62024-1 covers high-frequency inductors of nominal size for surface mounting. IEC 60205 gives the method for calculating the effective parameters of magnetic piece parts (effective area, path length and volume) that the AL and B calculations rely on. The manufacturer’s datasheet remains the authority for AL, tolerance and saturation. Check the current edition of each document.1. N = √(100,000 / 523) = 13.83 turns.
2. Round to 14 turns: L = 523 × 14² = 102.5 µH (+2.5%). Thirteen turns gives 88.4 µH (−11.6%), so 14 is the pick.
3. B = 102.5 µH × 0.3 A / (14 × 13.3 mm²) = 165 mT, which is 66% of Bsat and under the 70% limit (175 mT).
4. Wire length = 14 × 40 mm = 0.56 m; Rdc = 1.72×10−8 × 0.56 / 1.96×10−7 m² = 49 mΩ.
At 1 A the same coil would reach 0.55 T, far beyond saturation.
- AL tolerance. A ±25% core gives ±12.5% in turns-for-a-target.
- Count turns correctly. One turn is one pass through the centre hole. Wire outside the core is not a turn.
- Saturation under DC bias. Inductance can drop sharply well before the current looks alarming.
- Self-resonance. Winding capacitance resonates with L and turns the inductor into a capacitor above that frequency.
- Wrong mix. A low-frequency mix has high loss at RF, and an RF mix has low AL and little noise attenuation at low frequency.
Turns Needed for Common Inductances
The table shows exact turns for typical toroid inductance factors. Fractional values are why you always round, then check what you actually get, because L moves with the square of N.
| Target L | AL = 100 nH | AL = 250 nH | AL = 523 nH | AL = 1000 nH |
|---|---|---|---|---|
| 10 µH | 10.0 | 6.3 | 4.4 | 3.2 |
| 22 µH | 14.8 | 9.4 | 6.5 | 4.7 |
| 47 µH | 21.7 | 13.7 | 9.5 | 6.9 |
| 100 µH | 31.6 | 20.0 | 13.8 | 10.0 |
| 220 µH | 46.9 | 29.7 | 20.5 | 14.8 |
| 470 µH | 68.6 | 43.4 | 30.0 | 21.7 |
| 1 mH | 100.0 | 63.2 | 43.7 | 31.6 |
Why One Turn Matters
Because L = AL N², a short winding is sensitive to turn count. Going from 14 to 15 turns raises inductance by 14.8%.
| Turns | L = AL × N² | One more turn |
|---|---|---|
| 5 | 13.1 µH | +44.0% |
| 10 | 52.3 µH | +21.0% |
| 14 | 102.5 µH | +14.8% |
| 20 | 209.2 µH | +10.3% |
| 30 | 470.7 µH | +6.8% |
| 50 | 1307.5 µH | +4.0% |
Wire Resistance and Current
Copper loss sets the working current as much as saturation does. Use the length N × mean turn length from the calculator, then compare with the figures below.
| Wire diameter | Resistance | Rule-of-thumb current |
|---|---|---|
| 0.2 mm | 547 mΩ/m | 0.09 A |
| 0.3 mm | 243 mΩ/m | 0.21 A |
| 0.5 mm | 88 mΩ/m | 0.59 A |
| 0.7 mm | 45 mΩ/m | 1.15 A |
| 1.0 mm | 22 mΩ/m | 2.36 A |
Worked Example: 47 µH Filter Choke
Given AL = 250 nH/N². N = √(47,000 / 250) = 13.71 turns, so use 14 turns. L = 250 × 14² = 49.0 µH, which is +4.3%. Thirteen turns gives 42.3 µH (−10.1%), so 14 is the better choice. Measure the finished part on an LCR meter, since the core tolerance is often ±25%, and trim by spreading or squeezing the winding.
Ferrite Inductor Questions
How do I calculate turns from AL?
N = √(L in nH / AL in nH per turn²). Round to a whole number and recompute L = AL × N² to see the error.
Where do I find AL?
On the core manufacturer’s datasheet, for the exact size and material. Do not reuse a value from a different mix or size.
Why is my measured inductance different?
Tolerance on AL is often ±25%, winding spacing matters, and permeability changes with frequency, temperature and DC bias. Always measure the finished coil.
How do I know if the core will saturate?
Calculate B = L × I / (N × Ae) and compare with the saturation flux density in the datasheet, leaving a margin for temperature.
Does the wire size affect inductance?
Not directly. It sets resistance, heating and whether the turns fit in the window. Thicker wire means fewer layers and a slightly different winding capacitance.
How do I get a lower inductance from the same core?
Use fewer turns. An air gap also lowers AL, which lets the inductor carry more DC current before saturation.