Series & Parallel Inductor Calculator
Combine inductors with or without coupling and find M, k and the equivalent inductance.
Step-by-step
- Enter valid values to begin.
Ideal inductors with no winding resistance, capacitance or core saturation, at a frequency well below self-resonance. Coupled modes use only L1 and L2 with mutual inductance M = k√(L1L2); aiding means the winding dots are connected so their fluxes add (series) or both currents enter the dotted ends (parallel). k must be below 1 for real windings; k = 1 is an ideal limit and k above 1 is non-physical and flagged. Measured series L values must be taken with the same LCR meter frequency and no DC bias.
Series and Parallel Inductors: When the Flux Talks Between Windings
Core Engineering Principles
Inductors in series add and in parallel combine like resistors, but only if their fields stay out of each other’s way. Put two coils close together and they share flux. The mutual inductance is M = k√(L₁L₂), where k runs from 0 for no coupling up to 1 for every line of flux linking both windings. In series, the fluxes either help or fight. Aiding gives L₁ + L₂ + 2M; opposing gives L₁ + L₂ − 2M. Two 10 µH windings at k = 0.9 read 38 µH aiding and just 2 µH opposing, nearly a factor of twenty apart from a swap of two wires.
That swap is the whole trick in a coupled SEPIC inductor, a common-mode choke or a flyback winding, and it is also how k is measured at the bench. Read the series-aiding and series-opposing inductance with an LCR meter, subtract, divide by four times the geometric mean, and k falls out. The parallel formulas need care: (L₁L₂ − M²) / (L₁ + L₂ ∓ 2M). A k above 1 is a measurement or arithmetic error, never a real part, because it would imply negative leakage inductance. Real windings reach roughly 0.95 to 0.99 with tight winding or a good core.
Parallel: Leq = (L1L2 − M²) / (L1 + L2 ∓ 2M) • k = (Laid − Lopp) / (4√(L1L2)) • E = ½LI²
NEC & Standard References
IEC 62024-1 covers high-frequency inductors of nominal inductance for electronic and telecommunications equipment, including how inductance, self-resonant frequency and rated current are specified. Manufacturer datasheets define the test frequency and DC bias for the inductance you read. IEEE Std 100 and IEC 60050 define self inductance, mutual inductance and the coupling coefficient. Check the dot convention printed on the part before wiring it.1. M = (38 − 2) / 4 = 9 µH.
2. k = 9 / √(10 × 10) = 0.90, which is a sensible value for a bifilar-wound core.
3. Check: (38 + 2) / 2 = 20 µH, which equals L₁ + L₂, so the meter readings agree.
4. Parallel aiding = (100 − 81) / (20 − 18) = 9.5 µH; parallel opposing = 19 / 38 = 0.5 µH.
5. Energy in the series-aiding connection = ½ × 38 µH × 2² = 76 µJ.
- Dot polarity decides everything. A reversed winding turns a 38 µH choke into 2 µH, and the converter may saturate or short.
- Don’t add inductors blindly. Two inductors sharing a core or sitting close together are coupled even if the schematic shows none.
- Opposing windings do not cancel energy storage. Leakage inductance still stores energy and causes switching spikes.
- Bias changes everything. Ferrite inductance drops as current rises, so the real L under load can be well below the meter reading.
- Never trust k above 1. Re-check the meter frequency, lead compensation and L₁ and L₂.
Uncoupled Inductors in Parallel
| L1 \ L2 | 1 µH | 10 µH | 100 µH | 1 mH | 10 mH |
|---|---|---|---|---|---|
| 1 µH | 0.5 µH | 0.9091 µH | 0.9901 µH | 0.999 µH | 0.9999 µH |
| 10 µH | 0.9091 µH | 5 µH | 9.091 µH | 9.901 µH | 9.99 µH |
| 100 µH | 0.9901 µH | 9.091 µH | 50 µH | 90.91 µH | 99.01 µH |
| 1 mH | 0.999 µH | 9.901 µH | 90.91 µH | 500 µH | 909.1 µH |
| 10 mH | 0.9999 µH | 9.99 µH | 99.01 µH | 909.1 µH | 5 mH |
Effect of Coupling
Dot polarity decides everything. Aiding connections add flux and increase inductance, opposing connections cancel it.
| k | Series aiding | Series opposing | Parallel aiding | Parallel opposing |
|---|---|---|---|---|
| 0 | 20.0 µH | 20.0 µH | 5.00 µH | 5.00 µH |
| 0.5 | 30.0 µH | 10.0 µH | 7.50 µH | 2.50 µH |
| 0.9 | 38.0 µH | 2.0 µH | 9.50 µH | 0.50 µH |
| 0.99 | 39.8 µH | 0.2 µH | 9.95 µH | 0.05 µH |
Worked Example: Two 22 µH Windings with k = 0.95
M = 0.95 × 22 = 20.9 µH. Series aiding is 44 + 2 × 20.9 = 85.8 µH and series opposing is 2.2 µH. Parallel aiding is (484 − 436.8) / (44 − 41.8) = 21.45 µH. Fully coupled in parallel, you would get about the same as one winding. Saturation current of the combined core still limits the design.
Series and Parallel Inductor Questions
How do I combine inductors in series?
Add them: Leq = L1 + L2 if they are not coupled.
How do I combine inductors in parallel?
1/Leq = 1/L1 + 1/L2 for uncoupled parts.
What is mutual inductance?
M = k √(L1L2). It changes the series and parallel totals by ±2M.
Why does a reversed winding matter?
Reversing one winding turns series aiding into series opposing and can reduce inductance dramatically.
How do I measure k?
k = (Laid − Lopp) / (4 √(L1L2)) from two series measurements.
Does the current rating add up?
In parallel the current rating roughly adds, but the combined saturation depends on the core and coupling.