Electronics & RFIEC 60751 RTD • Strain Gauge Practice

Wheatstone Bridge Calculator

Enter the four arms and excitation for balance and output, or switch to sensor mode for strain gauge and RTD bridges.

Vout = Vex (Rx/(R3 + Rx) − R2/(R1 + R2))  •  Balance: R1/R2 = R3/Rx  •  Quarter bridge: Vout ≈ Vex/4 × GF × ε
Calculated Result
—

Step-by-step

  1. Enter valid values to begin.

Layout used in every formula: excitation Vex is across the top and bottom nodes (bottom = 0 V). R1 is top-left, R2 bottom-left, R3 top-right, Rx bottom-right; the output is taken between the left midpoint (R1/R2) and the right midpoint (R3/Rx), Vout = Vright − Vleft, so it is positive when Rx rises above its balance value. The detector or amplifier is assumed to draw no current. In sensor mode all four arms start at R0; half bridge uses R3 = R0 − ΔR and Rx = R0 + ΔR, and full bridge uses R1 and Rx = R0 + ΔR with R2 and R3 = R0 − ΔR. Strain gauges commonly have a gauge factor near 2 and are 120, 350 or 1000 Ω; the 10 mW and 50 mW self-heating levels are typical rule-of-thumb figures, not standards, and depend on gauge size and the structure it is bonded to. RTD values use the Callendar–Van Dusen equation with the IEC 60751 coefficients (A = 3.9083×10−3, B = −5.775×10−7, C = −4.183×10−12); lead-wire resistance is ignored.

IEC 60751 RTD • ASTM E251 • Strain Gauge Practice

Wheatstone Bridge: Balance, Sensitivity and Self-Heating

Core Engineering Principles

We draw the bridge with R1 top-left, R2 bottom-left, R3 top-right and Rx bottom-right, excitation across the top and bottom nodes, and the output taken between the two midpoints. Each side is a voltage divider, so the output is the difference of two divider voltages. It is zero when R1/R2 = R3/Rx. The null is independent of excitation voltage and ignores changes that move all four arms equally, such as temperature.

With a strain gauge or RTD we look at tiny fractional changes, so the bridge arrangement decides the signal. One active arm, a quarter bridge, gives about Vex/4 × ΔR/R. Two arms that change oppositely give twice that, and four give four times, and they also cancel temperature and lead effects. The limit is heat. Every arm dissipates power, the gauge warms the structure it is bonded to, and the reading drifts. Excitation is therefore a trade between signal size and self-heating; gauge arms are usually kept near 10 mW or less on poor heat sinks, with more accepted only on a thick metal specimen.

Vout = Vex × (Rx / (R3 + Rx) − R2 / (R1 + R2))  •  Balance Rx = R2 × R3 / R1
Quarter Vout ≈ Vex/4 × GF × ε  •  half ×2, full ×4  •  Parm = I² R

NEC & Standard References

IEC 60751 defines industrial platinum resistance thermometers, with R0 = 100 Ω for a Pt100, a temperature coefficient of 0.00385 per °C and the Callendar–Van Dusen coefficients A and B (and C below 0 °C) used here. ASTM E251 sets test methods for the performance characteristics of metallic bonded resistance strain gauges, including gauge factor and temperature behaviour. Load-cell accuracy classes are covered by OIML R 60. Strain-gauge excitation and self-heating limits are manufacturer recommendations, not standard values, so check the gauge datasheet.
Worked Example: Checking an Unbalanced Bridge
Given: R1 = R2 = R3 = 1 kΩ, Rx = 1.1 kΩ, Vex = 5 V.
1. Left midpoint = 5 × 1 / 2 = 2.500 V.
2. Right midpoint = 5 × 1.1 / 2.1 = 2.619 V.
3. Vout = 2.619 − 2.500 = 119.05 mV, which is 23.81 mV/V.
4. Balance needs Rx = 1 × 1 / 1 = 1 kΩ, so the sensor is 100 Ω off.
5. Current = 2.500 + 2.381 = 4.88 mA, total power 24.4 mW, and 6.24 mW in Rx.
6. In sensor mode, a 350 Ω gauge with GF 2.0 at 1000 µε (ΔR = 0.7 Ω) gives 2.4975 mV at 5 V, but dissipates 17.9 mW; at 2.5 V it falls to 4.5 mW and 1.25 mV.
Safety & Installation Rules
  • Self-heating is a systematic error. The gauge warms, the specimen warms, and zero drifts; reduce excitation or use a pulsed supply.
  • Lead wires matter. A quarter bridge adds lead resistance to one arm; use a three-wire connection or a half or full bridge.
  • Don’t load the bridge. The output resistance can be hundreds of ohms, so use a high-impedance instrumentation amplifier.
  • Keep the sign convention. Swapping R3 and Rx with the amplifier inputs reverses the polarity.
  • Quarter-bridge non-linearity. At large strain use the exact formula.

Output Voltage for Small Imbalance

Output for R1 = R2 = R3 = 1 kΩ and Vex = 5 V.
RxVout
900 Ω-131.58 mV
950 Ω-64.10 mV
990 Ω-12.56 mV
1000 Ω0.00 mV
1010 Ω12.44 mV
1050 Ω60.98 mV
1100 Ω119.05 mV

Strain Gauge Outputs

Quarter-bridge output Vex/4 × GF × ε at 5 V and GF = 2.0.
StrainQuarterHalfFull
100 µε0.250 mV0.500 mV1.000 mV
500 µε1.250 mV2.500 mV5.000 mV
1000 µε2.500 mV5.000 mV10.000 mV
2000 µε5.000 mV10.000 mV20.000 mV

Self-Heating Limit

Power in one 350 Ω gauge, P = (Vex/2)² / R.
ExcitationPower per gauge
2 V2.9 mW
2.5 V4.5 mW
5 V17.9 mW
10 V71.4 mW

Worked Example: Finding an Unknown Resistor

With R1 = 2.2 kΩ, R2 = 4.7 kΩ and R3 = 1 kΩ, balance gives Rx = R2 × R3 / R1 = 2136 Ω. Adjust R3 until the detector reads zero, then compute Rx. Use a low excitation to avoid heating the arms.

Wheatstone Bridge Questions

How does a Wheatstone bridge work?

Two voltage dividers share an excitation. The difference between their midpoints is the output.

When is it balanced?

When Rx = R2 × R3 / R1, with zero output voltage.

Why use it for strain gauges?

It converts tiny resistance changes into measurable voltage and cancels common-mode effects.

What is a quarter, half or full bridge?

One, two or four active gauges. More gauges increase output and compensate for temperature.

How do I reduce self-heating?

Lower the excitation voltage. Keep power per gauge near 10 mW or less on poor heat sinks.

Does lead resistance matter?

Yes. Use a 3-wire or 4-wire connection to cancel lead errors.