HP ↔ kW Converter
Convert between horsepower definitions, kW and watts, with torque and nearest standard motor size.
Step-by-step
- Enter valid values to begin.
1 HP (mechanical) = 0.745699872 kW; 1 PS = 0.73549875 kW; 1 electrical HP = 0.746 kW exactly. The value is treated as shaft output power. Torque uses T = 9550 × kW / rpm. Input kW = shaft kW / efficiency and is optional context (set efficiency to 100 to see output only). Standard-size matching picks the closest listed rating, it does not choose a motor for you.
HP ↔ kW: Three Horsepowers and One Kilowatt
Core Engineering Principles
A kilowatt is a kilowatt everywhere on earth, but a horsepower is not. We carry three of them around. Mechanical (imperial) HP is 550 ft·lbf/s, which works out to 745.699872 W. Metric horsepower, the PS or CV on European and Japanese nameplates, is 75 kgf·m/s, or 735.49875 W. Electrical HP was rounded by the electrical trade to exactly 746 W. They look close enough to ignore, and that’s the trap: metric versus mechanical is a 1.4% gap.
The next thing to keep straight is which side of the motor the number describes. A motor’s rating, in kW or HP, is shaft output: the mechanical power it delivers to the coupling. The utility meter sees electrical input, which is output divided by efficiency, so a 37 kW motor at 93% draws about 40 kW. Speed ties it to torque, because power is torque times angular speed. At 1480 rpm a given output needs far more torque than at 2960 rpm, so convert power and then check the coupling, key and gearbox against the torque, not the horsepower figure.
T (N·m) = 9550 × kW / rpm • Pin = Pshaft / η
NEC & Standard References
IEC 60034-1 rates motors in kilowatts of shaft output and defines the duty types, and IEC 60034-30-1 sets the efficiency classes. NEMA MG-1 rates in horsepower, including the service factor, and lists the standard HP ratings. NEC Article 430 sizes conductors and protection from the full-load current tables (such as 430.250 for three-phase motors), which are indexed by horsepower, never by kilowatts and never by nameplate amps for the conductor itself. So a kW rating must be converted to the nearest table HP before you look anything up. Check the adopted code edition.1. kW = 50 × 0.745699872 = 37.285 kW, which is 37,285 W.
2. Metric: 37.285 / 0.73549875 = 50.69 PS.
3. Electrical HP: 37.285 / 0.746 = 49.98 HP.
4. Torque = 9550 × 37.285 / 1480 = 240.6 N·m, or 177.4 lb·ft.
5. Electrical input = 37.285 / 0.93 = 40.09 kW.
6. Nearest standard sizes: 37 kW on the IEC series and 50 HP on the NEMA series. A 37 kW replacement is 0.8% smaller than the original.
- Metric hp is not HP. Reading 50 PS as 50 HP, or the reverse, hides a 1.4% error on imported machines, enough to matter on a tightly sized drive.
- kW is output, not input. Size cables, breakers and generators on electrical input and current, not on the shaft rating.
- Service factor is not extra nameplate. A 1.15 service factor is reserve for abnormal conditions, and running there continuously shortens insulation life.
- Altitude and heat derate the motor. Standard ratings assume 1000 m and 40 °C ambient, and above that cooling air thins, so check the manufacturer curve.
- Pick the next size up when between ratings. Rounding down to the nearest standard size overloads the motor.
Common HP to kW Conversions
| Power | Mechanical HP in kW | Electrical HP in kW | Equivalent PS |
|---|---|---|---|
| 0.5 HP | 0.373 kW | 0.373 kW | 0.51 PS |
| 1 HP | 0.746 kW | 0.746 kW | 1.01 PS |
| 2 HP | 1.491 kW | 1.492 kW | 2.03 PS |
| 5 HP | 3.728 kW | 3.730 kW | 5.07 PS |
| 10 HP | 7.457 kW | 7.460 kW | 10.14 PS |
| 20 HP | 14.914 kW | 14.920 kW | 20.28 PS |
| 50 HP | 37.285 kW | 37.300 kW | 50.69 PS |
| 100 HP | 74.570 kW | 74.600 kW | 101.39 PS |
| 200 HP | 149.140 kW | 149.200 kW | 202.77 PS |
| 500 HP | 372.850 kW | 373.000 kW | 506.93 PS |
IEC Motor Sizes in HP and Torque
| kW | HP | Torque |
|---|---|---|
| 0.37 kW | 0.50 HP | 2.4 N·m |
| 0.75 kW | 1.01 HP | 4.9 N·m |
| 1.1 kW | 1.48 HP | 7.2 N·m |
| 1.5 kW | 2.01 HP | 9.9 N·m |
| 2.2 kW | 2.95 HP | 14.5 N·m |
| 3 kW | 4.02 HP | 19.8 N·m |
| 4 kW | 5.36 HP | 26.3 N·m |
| 5.5 kW | 7.38 HP | 36.2 N·m |
| 7.5 kW | 10.06 HP | 49.4 N·m |
| 11 kW | 14.75 HP | 72.4 N·m |
| 15 kW | 20.12 HP | 98.8 N·m |
| 18.5 kW | 24.81 HP | 121.8 N·m |
| 22 kW | 29.50 HP | 144.9 N·m |
| 30 kW | 40.23 HP | 197.6 N·m |
| 37 kW | 49.62 HP | 243.7 N·m |
| 45 kW | 60.35 HP | 296.4 N·m |
| 55 kW | 73.76 HP | 362.2 N·m |
| 75 kW | 100.58 HP | 494.0 N·m |
| 90 kW | 120.69 HP | 592.8 N·m |
| 110 kW | 147.51 HP | 724.5 N·m |
Torque Depends on Speed
The same power needs more torque at lower speed, so check couplings and gearboxes against torque.
| Speed | Torque | Torque |
|---|---|---|
| 750 rpm | 474.8 N·m | 350 lb·ft |
| 1000 rpm | 356.1 N·m | 263 lb·ft |
| 1480 rpm | 240.6 N·m | 177 lb·ft |
| 2960 rpm | 120.3 N·m | 89 lb·ft |
Worked Example: Replacing a 7.5 HP Pump Motor
7.5 HP = 7.5 × 0.7457 = 5.59 kW, so the nearest IEC sizes are 5.5 kW (1.6% below the old rating) and 7.5 kW (34% above it). Pick 5.5 kW if the load is known to be near the old motor’s rating, or 7.5 kW if you need margin. At 1450 rpm the shaft torque is 36.8 N·m at 5.59 kW and 49.4 N·m at 7.5 kW. At 90% efficiency the electrical input is 8.33 kW.
HP to kW Questions
How many kW is 1 HP?
1 mechanical horsepower is 0.7457 kW. Electrical HP is defined as exactly 746 W.
How do I convert kW to HP?
Divide kW by 0.7457. For example, 11 kW is 14.75 HP.
What is PS?
Metric horsepower, equal to 0.7355 kW. It is about 1.4% smaller than mechanical HP.
Is motor rating input or output?
Output on the shaft. Electrical input is larger by the efficiency.
How do I get torque from power?
T (N·m) = 9550 × kW / rpm.
What is a service factor?
A reserve for abnormal conditions, not extra nameplate. Continuous operation at the service factor shortens insulation life.