← Back to ElectroLab
Energy & BillingIEC 60034 • NEMA MG-1 • NEC 430

HP ↔ kW Converter

Convert between horsepower definitions, kW and watts, with torque and nearest standard motor size.

1 HP = 0.745699872 kW  •  1 PS = 0.73549875 kW  •  1 HP(elec) = 0.746 kW
Calculated Result
—

Step-by-step

  1. Enter valid values to begin.

1 HP (mechanical) = 0.745699872 kW; 1 PS = 0.73549875 kW; 1 electrical HP = 0.746 kW exactly. The value is treated as shaft output power. Torque uses T = 9550 × kW / rpm. Input kW = shaft kW / efficiency and is optional context (set efficiency to 100 to see output only). Standard-size matching picks the closest listed rating, it does not choose a motor for you.

IEC 60034 • NEMA MG-1 • NEC 430

HP ↔ kW: Three Horsepowers and One Kilowatt

Core Engineering Principles

A kilowatt is a kilowatt everywhere on earth, but a horsepower is not. We carry three of them around. Mechanical (imperial) HP is 550 ft·lbf/s, which works out to 745.699872 W. Metric horsepower, the PS or CV on European and Japanese nameplates, is 75 kgf·m/s, or 735.49875 W. Electrical HP was rounded by the electrical trade to exactly 746 W. They look close enough to ignore, and that’s the trap: metric versus mechanical is a 1.4% gap.

The next thing to keep straight is which side of the motor the number describes. A motor’s rating, in kW or HP, is shaft output: the mechanical power it delivers to the coupling. The utility meter sees electrical input, which is output divided by efficiency, so a 37 kW motor at 93% draws about 40 kW. Speed ties it to torque, because power is torque times angular speed. At 1480 rpm a given output needs far more torque than at 2960 rpm, so convert power and then check the coupling, key and gearbox against the torque, not the horsepower figure.

1 HP (mech) = 0.745699872 kW  •  1 PS = 0.73549875 kW  •  1 HP (elec) = 0.746 kW
T (N·m) = 9550 × kW / rpm  •  Pin = Pshaft / η

NEC & Standard References

IEC 60034-1 rates motors in kilowatts of shaft output and defines the duty types, and IEC 60034-30-1 sets the efficiency classes. NEMA MG-1 rates in horsepower, including the service factor, and lists the standard HP ratings. NEC Article 430 sizes conductors and protection from the full-load current tables (such as 430.250 for three-phase motors), which are indexed by horsepower, never by kilowatts and never by nameplate amps for the conductor itself. So a kW rating must be converted to the nearest table HP before you look anything up. Check the adopted code edition.
Worked Example: Imported 50 HP Machine on a 1480 rpm Drive
Given: 50 mechanical HP, 1480 rpm, efficiency 93%.
1. kW = 50 × 0.745699872 = 37.285 kW, which is 37,285 W.
2. Metric: 37.285 / 0.73549875 = 50.69 PS.
3. Electrical HP: 37.285 / 0.746 = 49.98 HP.
4. Torque = 9550 × 37.285 / 1480 = 240.6 N·m, or 177.4 lb·ft.
5. Electrical input = 37.285 / 0.93 = 40.09 kW.
6. Nearest standard sizes: 37 kW on the IEC series and 50 HP on the NEMA series. A 37 kW replacement is 0.8% smaller than the original.
Safety & Installation Rules
  • Metric hp is not HP. Reading 50 PS as 50 HP, or the reverse, hides a 1.4% error on imported machines, enough to matter on a tightly sized drive.
  • kW is output, not input. Size cables, breakers and generators on electrical input and current, not on the shaft rating.
  • Service factor is not extra nameplate. A 1.15 service factor is reserve for abnormal conditions, and running there continuously shortens insulation life.
  • Altitude and heat derate the motor. Standard ratings assume 1000 m and 40 °C ambient, and above that cooling air thins, so check the manufacturer curve.
  • Pick the next size up when between ratings. Rounding down to the nearest standard size overloads the motor.

Common HP to kW Conversions

Mechanical HP, electrical HP and metric PS expressed in kW.
PowerMechanical HP in kWElectrical HP in kWEquivalent PS
0.5 HP0.373 kW0.373 kW0.51 PS
1 HP0.746 kW0.746 kW1.01 PS
2 HP1.491 kW1.492 kW2.03 PS
5 HP3.728 kW3.730 kW5.07 PS
10 HP7.457 kW7.460 kW10.14 PS
20 HP14.914 kW14.920 kW20.28 PS
50 HP37.285 kW37.300 kW50.69 PS
100 HP74.570 kW74.600 kW101.39 PS
200 HP149.140 kW149.200 kW202.77 PS
500 HP372.850 kW373.000 kW506.93 PS

IEC Motor Sizes in HP and Torque

Standard IEC motor sizes in HP, with torque at about 1450 rpm (four-pole, 50 Hz).
kWHPTorque
0.37 kW0.50 HP2.4 N·m
0.75 kW1.01 HP4.9 N·m
1.1 kW1.48 HP7.2 N·m
1.5 kW2.01 HP9.9 N·m
2.2 kW2.95 HP14.5 N·m
3 kW4.02 HP19.8 N·m
4 kW5.36 HP26.3 N·m
5.5 kW7.38 HP36.2 N·m
7.5 kW10.06 HP49.4 N·m
11 kW14.75 HP72.4 N·m
15 kW20.12 HP98.8 N·m
18.5 kW24.81 HP121.8 N·m
22 kW29.50 HP144.9 N·m
30 kW40.23 HP197.6 N·m
37 kW49.62 HP243.7 N·m
45 kW60.35 HP296.4 N·m
55 kW73.76 HP362.2 N·m
75 kW100.58 HP494.0 N·m
90 kW120.69 HP592.8 N·m
110 kW147.51 HP724.5 N·m

Torque Depends on Speed

The same power needs more torque at lower speed, so check couplings and gearboxes against torque.

Torque at 37.285 kW (50 HP) for different speeds: T = 9550 × kW / rpm.
SpeedTorqueTorque
750 rpm474.8 N·m350 lb·ft
1000 rpm356.1 N·m263 lb·ft
1480 rpm240.6 N·m177 lb·ft
2960 rpm120.3 N·m89 lb·ft

Worked Example: Replacing a 7.5 HP Pump Motor

7.5 HP = 7.5 × 0.7457 = 5.59 kW, so the nearest IEC sizes are 5.5 kW (1.6% below the old rating) and 7.5 kW (34% above it). Pick 5.5 kW if the load is known to be near the old motor’s rating, or 7.5 kW if you need margin. At 1450 rpm the shaft torque is 36.8 N·m at 5.59 kW and 49.4 N·m at 7.5 kW. At 90% efficiency the electrical input is 8.33 kW.

HP to kW Questions

How many kW is 1 HP?

1 mechanical horsepower is 0.7457 kW. Electrical HP is defined as exactly 746 W.

How do I convert kW to HP?

Divide kW by 0.7457. For example, 11 kW is 14.75 HP.

What is PS?

Metric horsepower, equal to 0.7355 kW. It is about 1.4% smaller than mechanical HP.

Is motor rating input or output?

Output on the shaft. Electrical input is larger by the efficiency.

How do I get torque from power?

T (N·m) = 9550 × kW / rpm.

What is a service factor?

A reserve for abnormal conditions, not extra nameplate. Continuous operation at the service factor shortens insulation life.