Solar Panel Array Sizing Calculator

Enter daily energy use, site peak sun hours and an itemised loss budget to find the array size, panel count, area and annual yield.

kWp = kWh/day × (1 + margin) / (PSH × DF)  •  DF = Π(1 − lossi)
Calculated Result
—

Step-by-step

  1. Enter valid values to begin.

Method: kWp = daily demand × (1 + margin) / (PSH × derating), where derating is the product of (1 − each loss). The loss percentages are typical planning values, not measurements; a site model such as PVWatts or PVsyst will refine them. PSH is the daily plane-of-array irradiation in kWh/m² (equivalent hours at 1 kW/m²). Off-grid mode lifts demand by the battery round-trip loss on the share of energy that passes through the battery. Annual yield assumes the same PSH every day. Verify the NEC edition and local AHJ requirements before design.

NEC Article 690 • IEC 61215 • IEC 61730 • PV Array Sizing

Solar Array Sizing: From Daily kWh to a Panel Count

Core Engineering Principles

Every array sizing job starts with one number, peak sun hours. A PSH of 5 does not mean five hours of daylight. It means the day’s irradiation equals five hours at 1 kW/m², the condition at which a panel earns its nameplate rating. Divide daily energy by PSH and you get the kWp for a perfect world. We never get one, so the second number is the derating factor, or performance ratio, and the way to get it right is to itemise it. Hot cells lose 5–12% in summer, dust takes 2–5%, wiring 1–2%, the inverter about 4%, and mismatch and first-year degradation a point or two each. Multiply them as (1 − loss) terms, never add them; a typical rooftop lands near 0.80–0.85.

Round the panel count up, then look at what you built: twenty-one 400 W modules is 8.4 kWp, not 8.1, and the extra is free margin. Off-grid, every kWh passed through a battery pays the round-trip loss, so the array must be bigger than the load suggests. We add a margin of 10–20% because panels degrade about 0.5% per year and loads creep upward. Size for the worst month you care about, not the annual average, or the battery will tell you about it in January.

DF = (1 − Ltemp)(1 − Lsoil)(1 − Lwire)(1 − Linv)(1 − Lmis)(1 − Ldeg)
kWp = Eday × (1 + margin) / (PSH × DF)  •  N = ⌈ kWp × 1000 / Wpanel ⌉
Off-grid: Eeff = E × (1 − s + s / ηrt)

NEC & Standard References

NEC Article 690 governs PV systems: maximum voltage with temperature correction in 690.7, circuit sizing at 125% of short-circuit current in 690.8, plus overcurrent protection, disconnects and rapid shutdown. IEC 61215 qualifies the design of crystalline silicon modules and IEC 61730 covers their safety construction. For inverters see IEC 62109 and UL 1741. This tool sizes energy only; string voltage and conductors are separate checks. Verify the adopted NEC edition and the requirements of your local authority having jurisdiction (AHJ).
Worked Example: Grid-Tied Home, 30 kWh per Day
Given: 30 kWh/day, PSH 5.0, losses temperature 8%, soiling 3%, wiring 2%, inverter 4%, mismatch 2%, degradation 1%, margin 10%, 400 W panels of 1.95 m².
1. DF = 0.92 × 0.97 × 0.98 × 0.96 × 0.98 × 0.99 = 0.815.
2. kWp = 30 × 1.10 / (5.0 × 0.815) = 8.10 kWp.
3. Panels = 8,103 W / 400 W = 20.26, rounded up to 21 panels, which is 8.40 kWp installed.
4. Output = 8.40 × 5.0 × 0.815 = 34.21 kWh/day, or 114% of demand.
5. Area = 21 × 1.95 = 40.9 m² (441 ft²) and annual yield = 34.21 × 365 = 12,487 kWh.
Safety & Installation Rules
  • Use the winter PSH for off-grid. An annual average hides a December that may deliver half as much sun.
  • Shade kills strings. One shaded cell pulls a whole series string down.
  • Don’t stop at energy. Cold-morning voltage can exceed inverter limits.
  • Roof area is not array area. Fire setbacks and vents often remove 30% or more.
  • Never assume zero degradation. Use the warranty curve when a contract guarantees yield.

How Many Solar Panels Do I Need?

The table shows the number of 400 W panels for a grid-tied system using the example derating of 0.815 and a 10% margin from the worked example. Off-grid systems need more because of battery losses. The result depends strongly on your local sun hours.

400 W panels needed (derating factor 0.815, 10% margin, grid-tied)
Daily use3 sun hours4 sun hours5 sun hours6 sun hours
5 kWh6543
10 kWh12976
15 kWh1713119
20 kWh23171412
30 kWh34262117
40 kWh46342823

Peak Sun Hours by Region

Peak sun hours are the hours per day at 1,000 W/m² that equal the day’s sunshine energy. Use a figure for your site, and for off-grid use the winter value.

Typical peak sun hours (annual average, tilted panels)
Region typePSH
Cloudy northern climate2.5 – 3.5
Temperate (central Europe, northern USA)3.5 – 4.5
Sunny (southern USA, Mediterranean)5 – 6
Desert / equatorial5.5 – 7

Quick Estimate Without the Calculator

kWp needed = daily kWh ÷ (peak sun hours × 0.8). For 30 kWh a day at 5 sun hours that is 30 ÷ 4 = 7.5 kWp, close to the 8.1 kWp the full calculation gives with a 10% margin. Divide by the panel watts to get the number of panels.

What Does a System of This Size Produce?

Yearly output is kWp × PSH × DF × 365. An 8.4 kWp array at 5 PSH and 0.815 produces about 12,487 kWh a year, or 34 kWh a day on average. Real production changes with the season, shading and the roof angle.

Roof Area Needed

A typical 400 W module is about 1.95 m², so each kWp needs roughly 4.9 m² of roof. A 6 kWp system needs about 29 m² of clear area before setbacks and obstructions.

Solar Sizing Questions

How many solar panels do I need to power my house?

For a home using 30 kWh a day at 5 sun hours, about 21 panels of 400 W are needed (8.4 kWp). A home using 10 kWh a day needs about 7 panels. The number changes with sun hours, losses and the margin you add.

How do I calculate how many solar panels I need?

Divide your daily energy use by the peak sun hours and the derating factor to get kWp, then divide by the panel wattage and round up. The calculator above does the steps and shows the area and yearly yield.

What is a derating factor in solar sizing?

It is the combined effect of losses from heat, dust, wiring, the inverter, mismatch and ageing, multiplied together. A typical rooftop system is 0.80 to 0.85.

How many panels do I need for off-grid?

More than for grid-tied, since the energy that goes through the battery loses 10 to 20%. Size for the worst month, use the winter sun hours, and allow extra margin.

How much roof area do solar panels need?

About 1.95 m² per 400 W panel, so roughly 4.9 m² per kWp. Setbacks, vents and shading often remove 30% or more of the usable roof.

How many kWh does a 400 W panel produce per day?

At 5 peak sun hours and a derating of 0.815, one 400 W panel makes about 1.63 kWh per day. In a 3 sun hour location it produces about 0.98 kWh per day.